☎ 0 454 60 60 911📱 +90 545 632 00 28 info@giressmart.com · City centre / Giresun TRENعربي

Your camera, fire detection and access control systems in one place, working in harmony.

We survey your site in person, analyse the risks, then design, install, commission and maintain the system to fit your needs. Your systems should work together, not in isolation.

Survey & Design Installation & Commissioning Technical Service & Maintenance
Security cameras on a pole against a cloudy sky
CAMERA SYSTEMS

See, record, analyse

IP cameras, NVR and AI-powered video analytics.

Explore
Red fire alarm call point on a wall
FIRE DETECTION & ALARM

Detect early, evacuate safely

Addressable panels, detectors, manual call points and voice evacuation.

Explore
Electronic speed gates in a modern building lobby
ACCESS CONTROL & TIME ATTENDANCE

Who, where, when?

Cards, biometrics, turnstiles and staff attendance tracking.

Explore
01 Camera Systems

Smart security camera systems that see every corner clearly

We design IP camera systems not just as devices that "record", but as a security infrastructure that detects events, alerts you and provides evidence when needed. We manage the whole process in-house, from survey and camera selection to cabling and recording and monitoring software.

Up to 4K resolutionNight visionAI analyticsMobile viewing
Request a camera survey
Security cameras lined up on a wall
Wall-mounted white IP camera
Design based on pixel densityEach camera is chosen for the detail it needs to see.

High resolution

Options from 2 MP to 4K; cover wide areas with a single camera and keep detail when zooming.

Night vision

Clear recording in the dark with infrared (IR) lighting and sensors that deliver colour images in low light.

Video analytics

Meaningful alarms with human/vehicle classification, intrusion, line crossing and abandoned object detection.

Licence plate recognition

Reads and logs plates at entrances and exits; integrates with barrier and parking systems.

Thermal imaging

Early warning for perimeter security and for panels, equipment and stores at risk of overheating.

NVR and central management

Recorders sized for the retention period you need, plus multi-site monitoring software.

Remote access

Live view, playback search and event notifications from phone, tablet and computer.

Cybersecurity

Default passwords changed, a separate camera network (VLAN), permission levels and up-to-date firmware.

Which camera, where?

The right camera type, mounting point and lens angle avoid needless cost and leave no blind spots.

Dome camera

Its dome housing is discreet and impact-resistant; ideal indoors.

Office · corridor · shop

Bullet camera

Long-range outdoor camera with a deterrent look; strong for perimeter and car park monitoring.

Garden · façade · car park

PTZ (Speed Dome)

A camera that can be rotated and zoomed remotely; enables operator tracking over large areas.

Sites · ports · compound entrances

Fisheye / panoramic

180–360° view from a single device; reduces the number of cameras in open offices, lobbies and halls.

Lobby · open office · hall

Thermal camera

Builds the image from heat; detects people and hot spots even in darkness, fog and smoke.

Perimeter security · panels · storage
28 GS 911

Licence plate recognition (LPR)

Reads the plates of moving vehicles with high accuracy; enables automatic passage with white/black lists.

Compounds · factories · car parks

The right camera, the right detail: the DORI criteria

The EN 62676-4 standard defines how clearly a camera must see in pixels per metre. In our designs we position each camera for one of these targets. Click a level and see the difference.

IDENTIFICATION · establishing identity beyond doubt
Detection
25 px/m
Observation
62 px/m
Recognition
125 px/m
Identification
250 px/m
Recording Time Calculator

How much disk space do your cameras need?

Choose the number of cameras, the resolution and how many days of footage to keep; see the approximate storage required.

0
TB approx. storage
This calculation is an estimate based on average bit rates. Actual needs vary with scene motion, frame rate, night footage and camera model. The exact calculation is made during the site survey.
How Does Integrated Security Work?

Let's watch an incident unfold together

Systems installed separately only "keep records". Integrated systems notify each other and trigger the right response on their own . Choose a scenario and follow the steps.

22:40 WAREHOUSE OFFICE CORRIDOR ENTRANCE PANEL ROOM CANTEEN BACK DOOR Card reader Turnstile Magnetic contact IP camera Control panel Siren & strobe Emergency announcement Smoke detector Lighting Manager's phone

    Red fire alarm siren on a brick wall
    Ceiling-mounted detection device
    Early detection, controlled evacuationDetection, alarm and announcement work in a single scenario.
    02 Fire Detection & Alarm

    Systems that detect fire in the first seconds and send the right warning to the right place

    A fire detection and alarm system buys time for everyone in the building to evacuate safely. We select the panel, detector types and warning devices to suit the building's use, height and risk class, then design and commission the system in line with the relevant regulations and standards.

    Addressable and conventionalSmoke · heat · multi-sensorVoice evacuation (PA)TS EN 54 components
    Talk to us about a fire project

    System architecture: how does an addressable loop work?

    In an addressable system every device has its own address. The panel instantly shows which device in which room raised the alarm; because the loop is fed from both ends, a single cable fault does not disable the system.

    FIRE ALARMLoop 1 · Address 014Fire PanelAddressable control unit Optical smoke Smoke detected Heat detector Multi-sensor Manual callpoint Siren & strobe PA amplifiervoice evacuation Control moduledoors · lifts · ventilation Repeater panelsecurity / reception Manager notification

    System components

    Every area has a different risk profile; choosing the wrong detector leads to both delayed detection and false alarms.

    Addressable fire panel

    Monitors every device at its own address and shows the alarm location room by room. The standard solution for medium and large buildings.

    Conventional panel

    Reports alarms by zone; an economical and reliable solution for small businesses and single-storey buildings.

    Optical smoke detector

    Detects smoke particles entering the chamber; catches a fire before it bursts into flame. For offices, corridors and rooms.

    Heat detector

    Triggers at a fixed temperature or a rapid rise in temperature; preferred in kitchens, boiler rooms and car parks.

    Multi-sensor detector

    Evaluates smoke and heat together; increases sensitivity while reducing the risk of false alarms.

    Beam detector

    Covers large areas with a single beam in high-ceilinged warehouses, factories and sports halls.

    Aspirating smoke detection

    Continuously draws in air through pipes to detect smoke at a very early stage; ideal for server rooms.

    Manual call point

    Lets the person who notices a fire raise the alarm by hand; placed along escape routes and at exit doors.

    Siren and strobe

    Spreads the alarm to all areas with sound and light; strobes are critical for people with hearing impairments.

    Voice evacuation (emergency PA)

    Guides people calmly and correctly with recorded or live announcements; reduces the risk of panic.

    Input/output modules

    In a fire, stop ventilation, release doors and send lifts to the exit floor.

    Repeater panel and monitoring

    Shows the alarm simultaneously at security and reception points; graphic monitoring on the floor plan.

    How does a fire alarm unfold?

    In a well-designed system every step happens automatically within seconds.

    DetectionA detector senses smoke or heat, or a manual call point is pressed.
    Location and verificationThe panel shows the device address and the room it is in.
    Warning and evacuationSirens, strobes and voice announcements are activated in the relevant zones.
    Control scenariosDoors and turnstiles open, ventilation stops, lifts return to the exit floor.
    Notification and loggingManagers are notified; all events are logged with a timestamp.
    TS EN 54 seriesThe European series of standards that components such as panels, detectors, call points and warning devices must meet.
    Turkish Regulation on Fire Protection of BuildingsSets the detection and warning system requirements by building type and size.
    Periodic testing and maintenanceDetector tests, battery checks and reviewing panel logs keep the system ready at all times.
    03 Access Control & Time Attendance

    Access for the right person, at the right door, at the right time

    Access control systems define who may pass through which door and at what times, and log every passage. The same infrastructure becomes a Time & Attendance system (PDKS) for tracking working hours, shifts and timesheets. We configure card, biometric and turnstile solutions around how your organisation works.

    Card and mobile IDFingerprintFace recognitionTurnstileAttendance reports
    Request an access control survey
    Speed gates at a modern building entrance
    Fingerprint reader
    Access data = attendance dataThe same reader opens the door and records working hours.

    Authentication methods

    One or more methods are used together depending on the security level, number of users and traffic at the entry point.

    RFID card

    Fast and economical. Encrypted card technologies that are hard to clone (13.56 MHz) provide higher security.

    Office · factory · school

    Password / PIN

    Used as a second verification step together with a card, it significantly increases security.

    Server room · archive

    Fingerprint

    Unique to each person and no card to carry. Eliminates "buddy punching" in attendance tracking.

    Attendance · production areas

    Face recognition

    Contactless and fast; verifies people at busy entrances without creating queues.

    Lobby · staff entrance

    QR code and mobile ID

    Time-limited QR codes for visitors; card-free entry for staff via their phones.

    Visitors · shared offices
    28 GS 911

    Vehicle access by plate

    The plate recognition camera recognises registered vehicles, opens the barrier automatically and logs the passage.

    Compounds · car parks · campuses

    Hardware and functions

    The physical design of the entry point matters as much as the software.

    Tripod turnstile

    An economical, durable solution allowing one-by-one passage at staff and visitor entrances.

    Full-height turnstile

    A full-height gate that prevents climbing, for factory and facility entrances where perimeter security is critical.

    Speed gates

    Glass-wing, sensor-equipped, high-throughput gates for prestigious lobbies.

    Electromagnetic locks

    On office and technical room doors; wired to release automatically in a fire scenario.

    Visitor management

    Visitor registration, time-limited cards or QR codes, visit history and host notification.

    Anti-passback

    Prevents consecutive entries with the same card; stops card sharing.

    Lift floor access

    Ensures users can only reach the floors they are authorised for.

    Fire integration

    On a signal from the fire panel, all doors and turnstiles are released for evacuation.

    PDKS · Time & Attendance

    Take attendance tracking off paper

    Entry and exit data from the readers is processed automatically according to the shifts and rules you define; preparing timesheets takes minutes.

    • Shift and flexible working-hour definitions
    • Late arrival, early departure and absence
    • Overtime calculation
    • Leave and sick-note tracking
    • Department and branch reports
    • Excel export for payroll
    Daily Attendance ReportSample view
    StaffInOutStatus
    Staff A07:5217:04On time
    Staff B08:1717:30Late in
    Staff C07:5819:12+2 h overtime
    Staff D——Annual leave
    All Low-Voltage Systems

    Our other systems for an integrated infrastructure

    Complementing camera, fire and access control systems, we design the entire security, communication and automation infrastructure as a single project. Choose a system.

    Intruder Alarm Systems

    Detectors on doors, windows and indoor areas connect to a control panel. If a breach occurs while the system is armed, the siren sounds and you and designated contacts are notified instantly.

    Wired / wirelessPIR detectorMagnetic contactMobile appZone management

    What does it provide?

    • Detects intrusion the moment it happens
    • Strong deterrence with siren and strobe
    • Arm / disarm from your phone
    • Zone-based use (e.g. only the warehouse armed at night)

    Components

    • Control panel: the brain of the system
    • PIR detector: detects movement by body heat
    • Magnetic contact: alerts when a door/window opens
    • Keypad, siren, battery: operation and backup power

    Tip

    If you have pets or an area that works at night, the right detector type and zone plan greatly reduce false alarms. When we integrate the alarm with cameras, the notification arrives with footage of the moment.

    Emergency PA & Sound Systems

    Manages zoned or general announcements, background music and emergency evacuation messages on a single infrastructure. Integrated with the fire panel, it guides evacuation by voice.

    Zoned announcementsRecorded evacuation messageBackground musicLine monitoringIP-based PA

    What does it provide?

    • Separate announcements for a floor, a zone or the whole building
    • Recorded evacuation message that plays automatically in an emergency
    • Announcements and background music for daily use
    • School bell system and scheduled announcements

    Components

    • PA exchange and amplifiers: the source and power of the sound
    • Microphone console: live announcements by selecting zones
    • Loudspeakers: ceiling, wall and outdoor (horn) types
    • Line monitoring: reports a broken cable instantly

    Intelligibility is everything

    In an emergency, loudness is not enough; the message must be understood. We choose speaker type, number and placement according to the room acoustics and noise level.

    Barriers, Parking & Plate Recognition

    Arm barriers regulate vehicle entry and exit. Plate recognition (LPR) cameras automatically recognise registered vehicles, open the barrier and log every passage with a photo.

    Arm barrierLicence plate recognitionLoop detectorPhotocellWhite / black listParking management

    What does it provide?

    • Controlled, orderly vehicle traffic
    • Fast, card-free passage for registered vehicles
    • Date, time and plate log of every entry and exit
    • Security for compounds, schools, factories and car parks

    Safety details

    • Photocells and in-ground loop detectors prevent the arm from coming down on a vehicle
    • Manual opening during power cuts
    • Arm length and speed are chosen to suit the lane width

    Repair or replace?

    In barriers worn over the years, mechanical and electronic parts tire together. After the survey we clearly report the total cost and the risk of repeat failure of repair alongside the replacement option; the decision is yours.

    Network, Structured Cabling & Fibre

    From cameras to phones, every system runs on the same infrastructure. Tidy structured cabling and the right switch and rack design mean speed, security and easy fault-finding.

    Cat6 / Cat6AFibre opticsPoE switchWi-FiVLANRack cabinetUPS

    Why does it matter?

    • Cameras, attendance, phones and internet on the same backbone
    • Fast fault-finding with labelled, tidy cabling
    • VLANs separate camera, guest and office networks
    • Uninterrupted operation during power cuts with a UPS

    Copper or fibre?

    • Cat6 copper: an economical solution up to 90 metres inside a building
    • Fibre optics: high speed between buildings and over long distances, immune to electrical interference

    Wi-Fi coverage

    The location and number of access points are determined by wall construction and user density. In large sites such as hotels, schools and factories, centrally managed access points let you roam the whole building as one network.

    IP Phones & PBX

    With an IP PBX, extensions run over the network; calls are routed to the right person, and branches and mobile staff can connect to the same PBX.

    IP / hybrid PBXVoice greetingCall recordingMobile extensionReporting

    What does it provide?

    • Voice greetings such as "Press 1 for sales"
    • Free calls between extensions
    • Calling as your company extension from a mobile phone
    • Missed call and call reports

    Who is it for?

    • Multi-department offices and hotels
    • Businesses with more than one branch
    • Teams that need call recording

    Plan it with the infrastructure

    IP phones can be powered from a PoE switch, so no separate adapter is needed. Designing the PBX together with the network project lowers cabling costs.

    Smart Building, PLC & Control Systems

    Runs equipment such as lighting, HVAC, pumps, doors and motors automatically with sensors and PLCs; you manage it from a single panel or your phone.

    Scenario automationPLCSensorsEnergy monitoringRemote control

    Example scenarios

    • When the last person leaves, the lights go off and the alarm is armed
    • The air conditioning turns down automatically in an empty room
    • The pump runs according to the water tank level
    • A notification reaches your phone in case of a fault

    What is a PLC?

    • A programmable controller designed for industrial environments
    • Manages equipment such as motors, valves and doors based on sensor data
    • Rugged and suitable for 24/7 continuous operation

    Energy saving

    The most tangible benefit of automation is cutting lighting and HVAC that run needlessly. A system that lets you monitor consumption also shows you where you can save.

    Modern corporate building with a glass façade
    "We design security not as a product, but as a system that works together."GIRESSMART · SMART LIVING, SAFE ENVIRONMENT
    About Us

    Engineering discipline in electronic security, precision in installation

    Giressmart is an engineering and installation company providing survey, design, installation, commissioning, technical service and consultancy in electronic security, IT and control systems. We design camera, fire detection and alarm, access control and all low-voltage systems under one roof to work together.

    We start every project by inspecting the site in person. We assess risks, use cases and budget together, and build a tidy, labelled infrastructure that puts the right product in the right place. After handover, periodic maintenance and technical service keep the systems ready at all times.

    From schools to hotels, factories to public institutions, we deliver scalable, standards-compliant and long-lasting solutions for buildings of every size.

    Our MissionTo make the security of organisations and living spaces sustainable through reliable technology and transparent engineering.
    Our VisionTo be the first partner that comes to mind for integrated security and smart building solutions, in our region and beyond.
    Engineering disciplineThe position of every camera, detector and reader is determined by calculation and standards.
    IntegrationSystems are not unaware of each other; they work as parts of a single security scenario.
    TransparencyClear quotes and open technical reports; repair or replace, you decide with full information.
    ContinuityWe stay with you after handover; a long-term partnership through maintenance and technical service.
    Our Project Process

    From survey to maintenance, step by step

    We follow the same discipline on every project, so you know from the start what will happen and when.

    Survey & Risk Analysis

    We inspect the site in person and identify entry points, blind spots and requirements.

    Design

    We plan camera, reader, detector and cable routes and present a clear quote.

    Installation

    We carry out cabling and mounting neatly, labelled and to standard.

    Testing & Commissioning

    We test every scenario and hand over after training your users.

    Maintenance & Support

    We keep the system running at all times with periodic maintenance and technical service.

    Sectors

    Solutions for businesses of every size

    We build systems shaped around your organisation's structure and daily operations.

    Schools & Education

    Security post, vehicle barrier, cameras and access control.

    Hotels & Hospitality

    Guest security, fire detection, Wi-Fi and IP phones.

    Factories & Production

    Attendance, turnstiles, site cameras and PLC-based control.

    Public Institutions

    Specification-compliant design, installation and IT infrastructure.

    Residential Compounds

    Plate recognition, parking, card entry and common-area security.

    Shops & Offices

    Intruder alarm, cameras, network and structured cabling.

    Healthcare Facilities

    Emergency PA, fire detection and controlled-area access.

    Smart Homes

    Home automation, alarms and remotely viewable cameras.

    Knowledge Corner

    Common questions, short and clear

    Click a card; the answer is on the back.

    01
    IP cameras or analogue cameras?
    See the answer

    IP cameras offer higher resolution, power over a single cable (PoE), smart analytics and easy expansion. Analogue (HD-TVI/AHD) systems can be a budget-friendly interim solution when existing coaxial cables need to be reused.

    02
    How many days of footage should I keep?
    See the answer

    Businesses usually choose 15–30 days ; incidents are sometimes noticed only days later. Some sectors may require longer periods by regulation or contract. You can see the disk requirement with the calculator .

    03
    What is PoE and why does it matter?
    See the answer

    Power over Ethernet means a device receives both data and power over the same network cable. Cameras, IP phones and access points need no separate socket or adapter; with a central UPS they all keep running during power cuts.

    04
    Smoke detector or heat detector?
    See the answer

    Optical smoke detectors catch a fire at an early stage and suit offices, corridors and rooms. In places with naturally occurring smoke or steam, such as kitchens and car parks, heat detectors are preferred to prevent false alarms.

    05
    Card access or face recognition?
    See the answer

    Cards are economical and fast but can be lost or handed to someone else. Face recognition and fingerprints are unique to each person; they eliminate "clocking in for a colleague" in attendance tracking. Most projects use both together.

    06
    Why is periodic maintenance necessary?
    See the answer

    Dust, humidity and batteries and disks that age over time can stop the system working exactly when you need it most. Regular maintenance includes lens cleaning, recording checks, battery tests, detector tests and software updates.

    Frequently Asked Questions

    Your questions

    For any question not answered here, you can contact us directly.

    Survey and quote

    Let us inspect your premises on site and prepare the most suitable system and a clear price quote for your needs.

    +90 545 632 00 28
    Which sectors do you serve?

    We provide solutions for organisations of every size, especially schools, hotels, factories, public institutions, residential compounds, shops and offices, healthcare facilities and homes.

    Can I view the cameras from my phone?

    Yes. After installation, live viewing and access to recordings are set up via a mobile app and computer; you can also decide who may see which cameras.

    Can you integrate my existing system without replacing it?

    In most cases, yes. During the survey we assess the condition and compatibility of your existing devices and propose a plan that keeps what can be reused and fills in the gaps.

    Does the fire detection system raise the alarm automatically?

    Yes. When a detector senses smoke or heat, the fire panel automatically activates sirens, strobes and the PA system; where integrated, it releases doors and turnstiles and notifies managers.

    Do the systems work during a power cut?

    Alarm and fire panels keep running on their internal batteries. Adding a suitably sized UPS for cameras, recorders and the network keeps recording and monitoring going during the outage.

    Do you provide maintenance and support after installation?

    Yes. We offer periodic maintenance and technical service. Frequency and scope are agreed together based on the type of system and how heavily it is used.

    How does the survey and quote process work?

    When you contact us by phone, WhatsApp or e-mail, we visit your site at a convenient time. After the inspection we send you a project and price quote tailored to your needs.

    Contact

    Let's talk about your project

    Fill in the form and your request goes straight to our team. You can also message us on WhatsApp.

    Your request goes straight to our team; we will call you back as soon as possible during working hours.
    Mobile / WhatsApp+90 545 632 00 28
    AddressŞeyh Keramettin Mah. Gazipaşa Sok. No:10/C, Merkez / GİRESUN
    Open the map in Google Maps Get Directions